E-MEM 2540 Industrial RO Membrane

Share on facebook
Share on google
Share on twitter
Share on linkedin

E-MEM 2540 Industrial RO Membrane

E-MEM residential membrane components are mainly used in various household water purifiers, mineralized direct drinking machines hospitals, and laboratories, and other small systems.

R1,725.00

E-MEM 2540 Industrial RO Membrane

E-MEM 2540 Industrial RO Membrane

 

Description

Active Membrane Area ft2(m2) Average Permeate GPD(m3/d) Stable Rejection Rate % Min. Rejection Rate %
30 (2.8) 750 (2.84) 99 98.5

 

TESTING CONDITIONS

  • Testing Pressure……. 150 psi (1.03Mpa)
  • Testing Solution Temperature……. 25 ℃
  • The concentration of Testing Solution (NaCl)……. 1500ppm
  • pH value of Testing Solution……. 7.5
  • Recovery Rate of Single Element……. 8%

OPERATION LIMITS & CONDITIONS

  • Max. Working Pressure……. 600psi(4.14Mpa)
  • Max. volume of Feedwater…… 6gpm(1.4 m3/h)
  • Max. temperature of Feedwater……. 45℃
  • Max. Feedwater SDI15……. 5
  • pH Range of Feed Water during Continuous Operation……. 3~10
  • pH Range of Feed Water during Chemical Cleaning……. 2~12
  • Residual Chlorine Concentration of Feed Water……. <0.1ppm
  • Max. Pressure Drop of Single Reverse Osmosis Membrane Element……. 15psi(0.1Mpa)
  • Max. Pressure Drop of Single Pressure Vessel with Six RO Membranes……. 50psi(0.34Mpa)
Weight 56 kg
Dimensions 122 × 121 × 451 cm
Brand

2540 800 GPD, 2540 800 GPD Vontron, 2540 800 GPD Filmtec, 2540 800 GPD HJC Membrane, 2540 800 GPD E-MEM Membrane, RO Membrane TW – 2540 HF, Vontron ULP21-2540

Reviews

There are no reviews yet.

Be the first to review “E-MEM 2540 Industrial RO Membrane”

Your email address will not be published. Required fields are marked *

Scroll to Top
× How can I help you?